StormTech | SC-740 Chamber - mc

By: Stormtech  09-12-2011
Keywords: Chamber

Proven engineering design just got bigger!

StormTech is pleased to announce the addition of the MC-4500 chamber to our family of products. This new product offers design engineers, contractors and owners yet another cost effective solution for managing stormwater.

Nominal MC-4500 Chamber Specifications
Chamber Size (W x H x Installed L) 100" x 60" x 48.3" 2540 mm x 1524 mm x 1227mm
Chamber Storage 106.5 ft3 3.02 m3
Chamber Weight 120 lbs 54.4 kg
Installed Storage Volume per Chamber
With 9" Stone Base 162.6 ft3 4.60 m3
With 12" Stone Base 166.3 ft3 4.71 m3
With 15" Stone Base 169.9 ft3 4.81 m3
With 18" Stone Base 173.6 ft3 4.91 m3
Nominal MC-4500 Endcap Specifications
Endcap Size (W x H x Installed L) 98.0" x 57.1" x 28.1" 2489 mm x 1450 mm x 714 mm
Endcap Storage 35.7 ft3 1.01 m3
Endcap Weight 120 lbs 54.4 kg
Installed Storage Volume per Endcap
With 9" Stone Base 108.7 ft3 3.08 m3
With 12" Stone Base 111.9 ft3 3.17 m3
With 15" Stone Base 115.2 ft3 3.26 m3
With 18" Stone Base 118.4 ft3 3.35 m3

Keywords: Chamber

Other products and services from Stormtech

09-12-2011

StormTech | SC-310 and SC-740 Endcaps - mc endcaps

The cored endcaps are set to match standard elevations and MC-4500 manifold parts.The MC-4500 manifold tees dry-fit into the pre-cored endcaps with no need for adhesives, screws, or couplers. The MC-4500 End Cap structural evaluation for both live and dead loads is comprised of computer modeling and field verification testing. The end cap is designed to withstand installation loads, wheel and deep cover loads as well as horizontal soil loads.


09-12-2011

StormTech | SC-310 Chamber

The StormTech SC-310™ is an ideal solution for Stormwater systems requiring low rise and wide span solutions. This low-profile chamber allows the storage of large volumes at minimum depths.


09-12-2011

StormTech Subsurface Stormwater Management

They have been evaluated to support HS-20 live loads following current AASHTO procedures for loads, structural capacity and factor of safety when installed per StormTech's Chamber Installation Instructions. StormTech chambers have been subjected to advanced in-ground testing and high-level industry expert review.


09-12-2011

StormTech | SC-740 Chamber - sc

Similar to 60" pipe systems, the SC-740™ chambers can prevent excessive excavation, backfill and associated costs. The StormTech SC-740™ Chamber optimizes storage volumes in relatively small footprints.