StormTech | SC-310 and SC-740 Endcaps - mc endcaps

By: Stormtech  09-12-2011

Rigorously Tested Structural Endcap

The MC-4500 End Cap structural evaluation for both live and dead loads is comprised of computer modeling and field verification testing. The end cap to chamber connection, end cap curvature and soil-end cap interaction influenced the end cap design. The end cap is designed to withstand installation loads, wheel and deep cover loads as well as horizontal soil loads.

MC-4500 endcaps can be ordered pre-cored for faster manifold assembly. The cored endcaps are set to match standard elevations and MC-4500 manifold parts.The MC-4500 manifold tees dry-fit into the pre-cored endcaps with no need for adhesives, screws, or couplers.

Above is a computer model of the MC-4500 end cap.

Nominal MC-4500 Endcap Specifications
Endcap Size (W x H x Installed L) 90.2" x 59.4" x 30.7" 2291 mm x 1509 mm x 781 mm
Endcap Storage 35.7 ft3 1.01 m3
Endcap Weight 120 lbs 54.4 kg
Installed Storage Volume per Endcap
With 9" Stone Base 108.7 ft3 3.08 m3
With 12" Stone Base 111.9 ft3 3.17 m3
With 15" Stone Base 115.2 ft3 3.26 m3
With 18" Stone Base 118.4 ft3 3.35 m3

Other products and services from Stormtech


StormTech | SC-740 Chamber - mc

This new product offers design engineers, contractors and owners yet another cost effective solution for managing stormwater. StormTech is pleased to announce the addition of the MC-4500 chamber to our family of products. Proven engineering design just got bigger. Installed Storage Volume per Chamber.


StormTech | SC-310 Chamber

The StormTech SC-310™ is an ideal solution for Stormwater systems requiring low rise and wide span solutions. This low-profile chamber allows the storage of large volumes at minimum depths.


StormTech Subsurface Stormwater Management

They have been evaluated to support HS-20 live loads following current AASHTO procedures for loads, structural capacity and factor of safety when installed per StormTech's Chamber Installation Instructions. StormTech chambers have been subjected to advanced in-ground testing and high-level industry expert review.


StormTech | SC-740 Chamber - sc

Similar to 60" pipe systems, the SC-740™ chambers can prevent excessive excavation, backfill and associated costs. The StormTech SC-740™ Chamber optimizes storage volumes in relatively small footprints.