Control Module

Turns Rock Stop’er system “on” or “off’

2. Sensor Status LED light

No light = Power Switch “OFF” or, Fault with power or ground circuit to Control Module

Green Light = Power Switch “ON” and Sensor circuit “OK”

Flashing Green/Red = Sensor Disconnected or other fault with sensor circuit wiring

- occurs simultaneously with a detection

3. Red Stop Light

Light On with Beeping = “Detection” (Sensor has been tripped .)

4. Reset· Push Button Switch

After the sensor has tripped the Red Stop Light is Flashing and a beeping sound is heard. Press the Reset Button to

acknowledge the detection. Then Reverse the feed drive to reset the forager stop system as would normally be done

after a metal detection. Shut off the main drive, and wait for all moving parts to stop moving before search ing for the

detected stone (or object) in the feed roll area.

5. Sensitivity Adjustment Dial

Adjusts the sensitivity of the sensor signal

10 = Most Sensitive

1 = Least Sensitive

Remember Higher Number = Higher Sensitivity

6. Wiring Harness Connector

1. On – Off Toggle switch
Turns Rock Stop’er system “on” or “off “

2. Sensor Status LED light
No light =
Power Switch “OFF” or, Fault with power or ground circuit to Control Module
Green Light =
Power Switch “ON”, Sensor circuit “OK”
Flashing Green/Red =
Sensor Disconnected or other fault with sensor circuit wiring   -
occurs simultaneously with a detection.

3. Red Stop Light
Light On with Beeping = “Detection”
(Sensor has been tripped .)

4. Reset · Push Button Switch
After the sensor has tripped the Red Stop Light is Flashing and a beeping sound is heard. Press the Reset Button to acknowledge the detection. Then Reverse the feed drive to reset the forager stop system as would normally be done after a metal detection. Shut off the main drive, and wait for all moving parts to stop, before searching for the detected stone (or object) in the feed roll area.

5. Sensitivity Adjustment Dial
Adjusts the sensitivity of the sensor signal
10 = Most Sensitive
1 = Least Sensitive
Remember Higher Number = Higher Sensitivity

6. Wiring Harness Connector

More information to come. Please check back soon.

Module on Claas

Module on John Deere

Module on New Holland

Keywords: Control Module, Sensor Circuit,

Other products and services from Rockstop

09-12-2011

RockStopper.com » Demonstration

The substantially uncompressable object causes a displacement of the upper feedroll at an acceleration rate greater than the substantially more compressable crop flow does. The ‘Sensor View’ shows the sensor move upward as the foreign object in the right clip reaches the front feed rolls.


09-12-2011

RockStopper.com » Sensor Unit

Sensor positioned almost vertical or parallel to the displacement travel of the front upper feedroll is the least sensitive setting for the sensor. To adjust the Sensor angle, slightly loosen the locknut, rotate the sensor to adjust the desired sensivity range. The Sensor angle determines the threshold at which the sensor will emit a signal due to feed roll movement.