Single Phase POWER WAVE




Specifications

  Power Rating 3, 5, 7.5, 10, 12.5, 15, and 20 KVA
2.1, 3.5, 5.25, 7, 8.75, 10.5 KW/KVA
  Input Voltage 3 & 5 KVA/KW;120, 208, 240, 277, or 480 VAC (-20% to +15%)
   7.5 - 15 KVA/KW; 208, 240, 277, or 480 VAC (-15% to +15%)
  Output Voltages 3 - 15 KVA/KW; 208, 240, 277, or 480 VAC
  Output Frequency
(Inverter Operation)
60 Hz ±0.5 Hz
  Voltage Regulation ±3%, Regulated within CBEMA curve
  Output Wave Form Sine-Wave < 5% THD.
  Efficiency Minimum 90%
  Crest Factor 3:1 Typical
  Surge Protection The UPS will protect itself and the load against surges as defined in ANSI/IEEE C62.41 Categories A and B.
  Isolation Complete from line. Output neutral bonded to ground
  Noise Isolation -120 dB Common-Mode; -60 dB Transverse-Mode
  Battery Sealed maintenance-free (AGM) battery
  Battery Volt KVA dependent
  Recharge Current Conforms to UL Standards
  External Battery Provisions for hardwire connection of optional external battery cabinets or DC source.
Environmental
  Humidity 0 - 95% RH w/ no condensation
  Operating Temperature UPS: 0° to 40°C. (32° - 104°F)
Battery: 20° to 30°C. (68° - 86°F)
  Storage Temperature -20° to 60°C. (-4° - 140°F)
  Altitude Up to 10,000 ft
  Safety Agencies CUL, CSA Listed UL1778, UL924, UL924A,, MEA Approved; State Fire Marshal Approved (CA, NY, IL)
Cabinet Sizes (with Standard Battery Run Times) All model

W"
H"
D"
3 kVA/kW
39
x
48
x
18
5 kVA/kW
39
68
18
7.5 - 15 kVA/kW
51
70
30.5

       Copyright © 2002 Onlinepower, Inc. All rights reserved.

Keywords: Battery, Battery Cabinets, Cabinet Sizes, External Battery, Single Phase Power,

Other products and services from Online Power

09-12-2011

Welcome to Online Power, Inc - tbs

LU 750: 300 lbs. LU 1500: 450 lbs. 120 VAC or 208 VAC.


09-12-2011

Welcome to Online Power, Inc - harsh env

Suitable for Harsh Environment, Outdoor Applications AC Line Conditioning for Signals, Signs & Lighting Small Foot Print Meets NEMA Requirements Fail-Safe Provision Optional Global Monitoring System 2 year Factory Warranty. Provisions for hardwire connec-tionof optional external battery cabinets or DC source. Specifications are subject to change without prior notification. 120 (3 & 5 KVA only), 208, 240,or 277 VAC, +15% to -20.


09-12-2011

Welcome to Online Power, Inc - protector

Provisions for hardwire connec-tionof optional external battery cabinets or DC source. 120, 208, 240, 120/240, and 277 VAC (All Standard with output transformer. 120 (3 & 5 KVA only), 208, 240,or 277 VAC, +15% to -20. Other Cabinet Sizes dependent on Battery Run Time.