Refrigerant Recovery Units

By: Reftec  09-12-2011
Keywords: Cooling Systems, Refrigerant Recovery, Pressure Refrigerants

Refrigerant Recovery Systems: Oil-less Recovery Units, Commercial Recovery units

  • 6 Models Service Most Cooling Applications
  • Rapidly transfer hundreds or thousands of pounds of refrigerant
  • Service high or low pressure chillers
Model Refrigerant Vapor
Direct Liquid
Diablo R22 0.71 7.71 17.67
HandiVac R502 0.62 7.80 25
MityVac R22 1.56 n/a 55
Lite Evac R22 2.14 n/a 81
Evac Commercial R22 6.0 n/a 325
Allvac R22
Lovac R11 0.66 n/a 100
Lovac with Vacuum Pump R11 1.26 n/a 134

All recovery rates are certified through testing at AHRI official test centers


  • Dual 0.75-hp oil-less compressors
  • Services high pressure refrigerants

Twice the recovery capacity of typical oil-less recovery units.


  • 2.0-hp open drive compressor
  • Services high pressure refrigerants


  • Portable 110V recovery for commercial applications
  • 4 heavy duty casters for ease of mobility
  • Highest recovery capacity of any 110V unit

EVAC Commercial

  • 3-hp open drive compressor
  • All high pressure refrigerants

Blazing recovery rates to service chillers and other large cooling systems


  • Universal recovery of low (R123) and high (R22) pressure refrigerants.


  • 2-hp open drive compressor
  • Recovers R11, R123, R113
  • For all sizes of low pressure chillers

Lightweight, easy to use, high tolerance for noncondensible gases

LOVAC with Vacuum Pump

  • Integrated with 10.6 CFM Welch vacuum pump
  • Recovers R11, R123, R113 and other low pressure refrigerants
  • For all sizes of low pressure chillers

Fastest recovery rates of low pressure gas on the market

Keywords: Cooling Systems, Pressure Refrigerants, Refrigerant Recovery,

Other products and services from Reftec


Chiller Purge Systems

Flexible unit can supplement existing purge units on running chillers or distill gas from storage tanks - use on high or low pressure refrigerants. Configurations available for in door or out of door location as well as aggressive environments such as chlorine processing plants. Easily dispatched to solve noncondensible gas contamination emergencies. Chiller Purge Units: Service High or Low Pressure Cooling Systems.


Refrigerant Recovery and Storage Units

A full line of units that provide on-site recovery and storage for all refrigerants in a mobile package. High and low pressure refrigerant recovery and storage units available. ” liquid and vapor ports on tanks for greater recovery rates. Storage tanks from 120 gallons up to 1000 gallons and more. Capable of handling the largest tonnage chillers. Units mounted and hard piped on the ASME tanks. High Speed recovery of vapor and liquid.


The Worldwide Leader in Refrigerant Recovery - listcats

As a service provider in the HVAC and Commercial Recovery Recycling Equipment repair industry for over 19 years, we realize the value of quality designed and well built equipment. Reftec has always been ahead of the curve with equipment designs that almost double the recovery rates of competitive units of there class with very little sacrifice in weight.


The Worldwide Leader in Refrigerant Recovery - custom

There is no other company providing this type of product that meets all the specifications and service needs at a price which can be called acceptable for the job requirements. Peter Justice General Manager, Marinspect Refrigeration and Environmental Service, Dubai UAE. Reftec made what could be a problematic requirement an affordable and simplified process.


Refrigerant Storage cylinders and ASME tanks

RefTec 250 & 1000-lb D.O.T. tanks have been fitted with full 3/4” service valves and copper dip tubes to eliminate restrictions and allow faster refrigerant transfer. 250 & 1000-lb tanks are retrofitted with full 3/4" service valves & copper dip tubes to meet capacity of commercial recovery units. High capacity storage tanks accept complete high or low pressure refrigerant charges from large chillers.