Best Medical Canada - Build-up Caps

By: Thomson & Nielsen Electronics  09-12-2011

Full Photon Range & 15MeV - 18MeV Electrons

MOSFET dosimeters have only 0.8mm inherent build-up, which allows for flexibility in measuring surface dose as well as dose at Dmax. In order to measure dose at Dmax, build-up is required. Measuring accurate dose at depth is of primary concern for the physics community when performing patient dosimetry. Precise dose measurement verifies that the target volume area has been treated with the appropriate dose, while sparing surrounding tissue and organs. Current tissue-equivalent build-up caps require a different size for each energy. Best Medical Canada offers a custom designed Build-up Cap for use with MOSFET Dosimeters, which allows for depth dose measurements over a wide range of energies.

  • Maintains isotropic characteristics of the MOSFET dosimeter (±2% for 360°)
  • Lightweight (only 4g) and small (radius: 0.635cm)
  • Ideal for placement on patients
  • Specially grooved for precise placement of the MOSFET
  • May be affixed to the MOSFET for the duration of its life, i.e. 200 doses
  • Easier for therapists to use
  • Saves on patient set-up time
  • Only one build-up cap is required for all energies

Brass is a metal alloy containing mainly copper and zinc compounds. Due to its high density (8.5g/cm3) and to its high Z number (Z ~ 30), it provides the minimal amount of metal needed to achieve full build-up at Dmax for a range of photon energies (4, 6, 10 and 18MV) and some electron energies (15-18MeV)* at a very practical size.

*Note: For low electron energies, it is suggested that no build-up is used. However, if desired, one can use the 1.5cm radius tissue equivalent build-up cap (model TN-RD-55-1.5).

Manufactured exclusively for Best Medical Canada by CIRS using their Plastic Water™, these build-up caps come in sizes of 1cm, 1.5cm, and 2cm (models TN-RD-55-1, TN-RD-55-1.5, TN-RD-55-2 respectively) for various beam energies.  The build-up caps have grooves specifically made for MOSFET dosimeters, allowing accurate measurements.


Contact Thomson & Nielsen Electronics

Email - none provided

Print this page

Other products and services from Thomson & Nielsen Electronics

09-12-2011

Best Medical Canada - MOSFET DOSIMETRY

High sensitivity dosimeters in standard bias have 3 mV/cGy, while high sensitivity dosimeters used in high bias will yield a nominal sensitivity of 9 mV/cGy. Fits down a 6Fr catheter for dose verification during HDR brachytherapy procedures. Dose verification during radiotherapy treatments.


09-12-2011

Best Medical Canada - Phantoms Compatible with MOSFETs

With five dose points samples on the film and four dose points on an orthogonal plan, this QA procedure is adequate in theory and in practice.. This product was developed in association with Professor X. Wu, University of Miami, and is manufactured exclusively by Best Medical Canada. One of the planes, containing five MOSFET detection points, is the dividing plane of the two sub-phantoms where a film is housed.


09-12-2011

Best Medical Canada - Portable Dosimeter

The Portable Dosimeter supports up to two simultaneous dose points with any of the Best Medical Canada single MOSFETs on standard or high bias setting for optimal dose reproducibility. For one-to-two dose points, the Portable dosimeter is a fast, simple solution for patient dosimetry that can be used for a wide range of applications in radiotherapy and radiology.


09-12-2011

Best Medical Canada - mobileMOSFET

The system consists of Remote Monitoring Dose Verification Software, wall-mounted BlueTooth™ Wireless Transceiver, and a small Reader Module that acts as a channel between the MOSFET and software. This new wireless system is entirely software driven allowing for complete control of one or more systems from a remote PC. With multiple systems and transceivers, one PC can read MOSFETs in multiple treatment rooms simultaneously.