Midwest Electric Products, Inc - se

By: Midwest Electric Products  09-12-2011
Keywords: mobile homes, Galvanized Steel, Electrical Code

Application Information

Where electrical power enters a building or other structure, the National Electrical Code (NEC) requires electrical distribution equipment rated as "Service Entrance." Such service equipment usually consists of one main breaker disconnect or space for up to 6 submain disconnects. Midwest models meet these NEC requirements and are UL listed as service entrance equipment. These service entrance products are typically utilized on single family residences and mobile homes. Additionally, service entrance for mobile homes is generally located within 30 feet of the mobile home. This location requirement by the NEC and the common use of underground service feeders combine to make service entrance on a pedestal the preferred installation method by many park owners. Midwest offers a broad range of pedestal units, all factory assembled and wired with loop feed lugs to reduce installation time and labor expense. Midwest also offers a wide selection of surface units for single family residences and mobile home sites.

Features & Benefits

Rugged Durability:

  • Heavy G90 galvanized steel with highest quality electro-deposition finish resists corrosion and fading
  • 125, 200 or 320 Amp continuous duty meter socket with meter guides and reinforced jaws for ring and ringless type sockets

User Safety:

  • Utility meter socket compartment provides barrier from breaker mains for utility power protection
  • UL listed "Suitable for use as service equipment"
  • Rated NEMA 3R - weather proof equipment
  • Padlock provision on door to help prevent unauthorized access
  • Rolled edge post bottoms to protect service cable

Installation Ease:

  • All terminals accept copper or aluminum wire for added installation flexibility
  • Supplied with 12-2 Cu/Al equipment ground lug
  • Removable post door allows lay in wiring

Post models:

  • Factory wired loop feed lugs
  • Posts available with stud terminations to accept compression type lugs
  • Locking hasp for utility seal on post covers

Keywords: Aluminum Wire, Electrical Code, Equipment Ground, Galvanized Steel, Meter Socket, mobile homes,

Contact Midwest Electric Products

Email - none provided

Print this page

Other products and services from Midwest Electric Products

09-12-2011

Midwest Electric Products, Inc - rv

This application presents unique requirements including user safety, rugged construction, weather protection, receptacle versatility and attractiveness. Lighted units include a LED lamp rated for 100,000 hours - that's almost ten years without having to change a lamp. All components factory wired and assembled, reducing installation time. Continuous duty meter socket with meter guides and reinforced jaws.


09-12-2011

Midwest Electric Products, Inc - tppo

The single, heavy-gauge NEMA 3R rainproof enclosure is lockable and is engineered for maximum protection of receptacles, cords, plugs, breakers, and GFCI's. Many times, this requires several receptacles, over current protection and possibly a meter socket and GFCI, all designed for outdoor installation.


09-12-2011

Midwest Electric Products, Inc - ad

The 2002 National Electrical Code requires that a disconnecting means shall be located within sight from and readily accessible from the air-conditioning or refrigerating equipment. Our NEMA 3R air conditioner disconnect line is the largest offering in the industry and is built with the same quality features which are found in all Midwest products.


09-12-2011

Midwest Electric Products, Inc

Our manufacturing facility houses state of the art fabrication equipment which allows us to produce the highest quality product in the most cost efficient manner. Midwest Electric Products offers almost 60 years of experience in manufacturing the highest quality outdoor electrical equipment. Heavy zinc-coated galvanized steel with high quality electro-deposition paint finish for maximum corrosion protection.