 Digital Calibrated Sequential Compression Circulator

Model No. Whf-314

  •  HCPCS : E0652, E0651

  • Lymphedema, Venous Insufficiency, DVT Prophylaxis, Arterial Flow Therapy System

  • Individual Pressure Setting of Each Chamber

  • 8 Compression Mode

  • Graphic LCD Window

  • Adjustable Inflation : 5 sec ~ 21 sec

  • Adjustable Deflation : 0 sec ~ 45 sec

  • Skip Pressure ("0" mmHg) Setting

  • Selection Part Compression Mode

  • Time Range : 99 min

  • Dimentions : 8" (W) x 8" (L) x 5.5" (H)

  • Single or Bilateral Garment Available

 

Mode A1 : Calibrated Sequential Pressure Mode (Foot to Thigh)

Mode A2 : Calibrated Sequeintial Pressure Mode (Thigh to Foot)

Mode B : Arterial Flow Compression Mode

Mode C : Gradient Sequeintial Compression Mode

Mode 1 : DVT Compression Mode (Foot Only)

Mode 2 : DVT Compression Mode (Calf Only)

Mode 3 : Knee Compression Mode

Mode 4 : Thigh Compression Mode

  •  INDICATION : Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Venous Insufficiency, DVT Prophylaxis

  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

Gradient Pneumatic Sequential Compressor

Model No.  P1000-T

(Best for Blood and Lymph Fluid Circulation)

(9 seconds each chamber) :

Chamber 1 (Foot) - 36 sec, Chamber 2 (Ankle) - 27 sec, Chamber 3 (Calf) - 18 sec, Chamber 4 - 9 sec

1st chamber 9 sec - 2nd chamber 7 sec - 1,2nd chamber 2 sec - 3rd chamber 7 sec - 1,2,3rd chamber 2 sec - 4th chamber 7 sec - 1,2,3,4th sec 2 sec - 24 sec deflation all 4 chambers - repeat

  •   INDICATION : Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Poor Blood Circulation, etc

  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

Model No. P1000-TW

 (Intermittent None Segmental Compression Mode)

  • Pressure: 20 ~ 100 mmHg (low pressure, safe)

  • Easy to set pressure

  • 60 min timer

  • Cycle Time:   Inflation:   36 seconds (1st chamber to 4th chamber at the same time / Deflation: 24 seconds (at the same time)

 

  •     INDICATION : Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Poor Blood Circulation, etc

  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

  

 

Model No. P1000

(Best for Blood and Lymph Fluid Circulation)

(9 seconds each chamber) :

Chamber 1 (Foot) - 36 sec, Chamber 2 (Ankle) - 27 sec, Chamber 3 (Calf) - 18 sec, Chamber 4 - 9 sec

1st chamber 9 sec - 2nd chamber 7 sec - 1,2nd chamber 2 sec - 3rd chamber 7 sec - 1,2,3rd chamber 2 sec - 4th chamber 7 sec - 1,2,3,4th sec 2 sec - 24 sec deflation all 4 chambers - repeat

  •   INDICATION : Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Poor Blood Circulation, etc

  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

Model No. P1000-W

   (Intermittent None Segmental Compression Mode)

  •  Pressure:  30 ~ 120 mmHg 

  • Acurate Pressure Set up
  • Pressure Lock System

  • Cycle Time:   Inflation:   36 seconds (1st chamber to 4th chamber at the same time / Deflation: 24 seconds (at the same time)

 

  •     INDICATION : Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Poor Blood Circulation, etc

  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

Model No.  P1000-TM

  (Best for Massage)

  • Pressure:  40 ~ 230 mmHg (high pressure)
  • 60 min timer
  •  Cycle Time:  15 seconds each chamber

1st chamber 15 sec - 2nd chamber 15 sec - 1st chamber deflation - 3rd chamber 15 sec - 2nd chamber deflation - 4th chamber 15 sec - 3rd chamber deflation - 1st chamber 15 sec - 4th chamber deflation - repeat


  • INDICATION : Painful, Swollen Leg & Feet / Cold, Heavy ,Stiffness, Tension Legs or Muscles

Calibrated Gradient Compression Circulator

Adjustable Each Chamber Pressure

Model No.  P1000-CG

(Best for Blood and Lymph Fluid Circulation)

  • Pressure: 30 ~ 100 mmHg

  • Gradient Sequential Operation

  • Cycle Time: Inflation:   36 seconds / Deflation: 24 seconds 

(9 seconds each chamber) :

Chamber 1 (Foot) - 36 sec, Chamber 2 (Ankle) - 27 sec, Chamber 3 (Calf) - 18 sec, Chamber 4 - 9 sec


  • INDICATION: Lymphedema (primary, secondary), Oedema (dependent, traumatic, secondary to stroke), Venous Insufficiency, Venous Stasis, Pain, Swelling, Wound Therapy caused by Poor Blood Circulation, etc
  • CONTRAINDICATION : Severe arteriosclerosis or other ischemic vascular disease, Known or suspected acute deep vein thrombosis, Severe congestive cardiac failure, Any local condition in which garments would interfere, for examples Gangrene, Untreated, infected leg wounds, recent skin graft, dermatitis.

How to set up Chamber pressure?

Main pressure setting is same as Model No P1000

*** Caution: Set pressure with Main Pressure Knob, before you adjust other chambers. 

 *** To set chamber pressure(1 ~ 4): While air inflates, Turn chamber knob to desired pressure. Or  Place finger over and close Air supply port which are inflates, then quickly adjust the chamber knob to desired pressure.

Keywords: Lymphedema

Other products and services from Neomedic

09-12-2011

Neomedic - Portable Massage Chair

Fully Adjustable Chest Pad and Arm Rest for Improved Client Comfort. Integrated Wheels for Easy Portability. Ergonomic Sure Grip Soft Knobs.


09-12-2011

Neomedic - Infrared Heating Lamp

Beneficial effects include decrease joint stiffness, increased vasodilation, muscle spasm relief and reduced pain from ligamentous sprains and strains. Arthritis Rheumatism, Tennis Elbow, Shoulder, Neck pain, Injuries of muscle, etc. Sports Injuries Injuries of muscle, wrist and hand, tendon, tennis elbow. External Medicine Arthristis rheumatism, Neuralgia lumbago. Others - Paralysis, Acupuncture, Facial paralysis.