KL-6001 Advance Room Control

By: Itb Canada  09-12-2011
Keywords: Ventilation, Climate Control, Exhaust System


  • Easy operation with large display;

  • Suitable for a single room;

  • Central exhaust system with frequency control or step controlled fans;

  • ECOVENT-system;

  • Precise climate control by AQC-UNIT;

  • Central control functions for ventilation and heating;

  • Control of heat exchanger;

  • Modular structure by ST-bush;

  • Control of infra red heating;

  • Connection with PC.


Most Advanced Room Controller

The KL-6001 Climate computer controls the climate in one (1) room. To ensure the KL-6001 is compatible with the situation in the barn, the KL-6001 is equipped with almost every control thinkable like air intake valves, air volume control through measuring fans and the capability to control a second fan. By using a large graphical display with clear symbols, the user can see in a blink of an eye, the actual situation in the room, and adjustments are easily made.

Depending on the application and fan type, the KL-6001 can be delivered with a 0-10V or 230V triac output for the fans.


KL-6001 (0-10 V)

The KL-6001 controls the ventilation level through a 0-10V control signal. This signal can be send to a frequency converter, EC-fan or triac power module, to control the RPMs of the fan.


KL-6001-6 / KL-6001-12 (triac, 230 Vac)

The KL-6001 is equipped with an internal triac, through which the connected fan speed is controlled directly. Depending on the connected power, the KL-6001 can be delivered with a 6 or 12 Amp fan output.


Climate Of Your Choice

The Kl-6001 controls the barn in such manner that the optimum relation between heating and ventilation is always guaranteed. To ensure the climate in the room grows with the animals, the KL-6001 has grow curves on all available controls. By taking the outside conditions in consideration, the control ensures the climate of your choice in the room. 

Energy Efficient Ventilation

When the KL-6001 is part of a central exhaust system or ECOVENT system, the fan speed is controlled by a frequency converter. The climate inside the room is accurately controlled with an AQC Air control unit by the climate computer


Central Controls

the KL-6001 is equipped with central controls, which eliminate the need for a central controller:

  • Ventilation:

    • Central exhaust through a frequency converter;

    • Central exhaust through a step control + speed controlled fans;

    • ECOVENT-system;

    • Minimum airspeed in chimneys through extra air supply.

  • Heating (cooling):

    • Central heat control;

    • Boiler control;

    • Central exhaust control;

    • Central air inlet control;

    • Heat exchanger


Windows PC software

To get an even better overview of your barn, the control system can be equipped with a software package for the PC, which collects the valuable data from the various controllers. This allows the user to detect any variations in an early stage, and in need be alterations can be made from the PC, ensuring the results stay optimum.


AQC-unit Air quantity control

An appropriate minimum ventilation level is required, to control the amount of CO2, humidity, ammonia and dust inside the room. The climate computer calculates the actual ventilation need based on the room temperature and the age of the animals.

An AQC-unit accurately measures and controls the outgoing airflow so the ventilation level is always just right, independent of the outside climatic conditions. The AQC-units are available in diameters from 30 up to 92 cm.

Keywords: Air Control, Air Control Unit, Climate Control, Computer Controls, Control Functions, Control Unit, Exhaust System, Frequency Control, Heating And Ventilation, Ventilation,

Other products and services from Itb Canada



Like the SPM series which is a triac based extension box that recieves a 0-10V signal from the main control and corolates that to a 0-100% output voltage great for controlling single phase fans or lights, or the EGM-100 Series winches, which are small winches capable of pulling 100Kg of weight with 24V supply power.


KL-6000 Multi Room Controller

When a KL-6000 is part of a central exhaust system or ECOVENT-system, a frequency controller will control the speed of the fans centrally. The KL-6000 controls the room climate to ensure the right balance between heating and ventilation at all times. The result is a climate computer that can be adjusted to your specific situation and optimum desires.



By using a complete plastic casing (50mm Polypropylene hollow-chamber-principle) every module is, besides UV- and cast-resistant also perfect insulated against noise and climatic influences. The complete construction has become thus strong that, under normal circumstances, damage during transport or use of the individual unit has been reduced to an absolute minimum.


Air2 Heat Regain Units

In order to simplify the choice for the correct heat-regain-unit for user and/or local dealer we have designed an extended standard kit, which, if needed with a limited number of options and extras, already provides a great number of possibilities for the relevant broiler building. Because of the smooth surface structure cleaning and maintenance has become very simple and efficient.


CBA-2000 Single Room Control

The CBA controls the building climate to ensure the right balance between heating and ventilation at all times. The CBA controls the building climate in one room where the fresh air comes in through air inlet valves. The CBA also monitors the room temperature. Ventilation and temperature at a glance. Data communication + Windows PC software. Min. & max. temperature alarm.