  • Target gas: 0-40,000 ppm hydrogen (in air)
  • Sensor type: Catalytic (with VOC filter)
  • Applications: Hydrogen-powered vehicles & fuel cell safety
  • Output signal: 0-3VDC, encoded state, TTL, or open drain
  • Bi-color indicator LED
  • Increased silicone tolerance and overexposure immunity
  • Powering options: 3VDC, 5-16VDC (~750mW)




  •  
  • Target gas: 0-25,000 ppm hydrogen (in air)
  • Sensor type: Catalytic (with VOC filter)
  • Applications: Fuel cells, general hydrogen safety
  • Output signal: 0-3VDC analog, 4-20mA analog, or TTL
  • Bi-color indicator LED and optional relay / alarm beeper
  • Increased silicone tolerance and overexposure immunity
  • Powering options: 3VDC, 6-40VDC, 6-55VDC (~1000mW)




  •  
  • Target gases: Trace H2/CH4, volume O2/H2/He
  • Sensor types: MOS, electrochemical, thermal conductivity
  • Applications: Trace sensing, percent volume measurement
  • Output signal: 10-bit analog (0-5VDC), state steps, or TTL
  • Bi-color indicator LED and optional relay / alarm beeper
  • Optional sensor head extension to 25 feet max.
  • Powering options: 5VDC, 7-40VDC, 7-60VDC (~500mW)




  •  
  • Target gases: Hydrogen, methane, propane, carbon monoxide
  • Sensor type: MOS (tin dioxide)
  • Applications: 0-50% LEL, 0-450 ppm CO
  • Output signal: 8-bit analog (0-5VDC) or TTL
  • Bi-color indicator LED and optional relay / alarm beeper
  • Powering options: 5VDC, 7-40VDC, 7-60VDC (~500mW)




  •  
  • Target gases: Combustibles, ammonia, R-21/22/113/134a
  • Sensor type: MOS (tin dioxide)
  • Applications: 0-80% LEL, 0-300 ppm NH3, 0-3000 ppm CFCs
  • Indicator LED and optional relay / alarm beeper
  • Connector options: Hirose 2mm header, terminal block/DC-jack
  • Powering options: 5VDC, 9-12VDC, 7-40VDC, 7-60VDC (~1W)
  • Open-frame OEM (embedded) versions available




  •  
  • Target gases: Hydrogen, methane, propane
  • Sensor type: MOS (tin dioxide)
  • Applications: 0-50% LEL
  • Output signal: 6-bit analog (0-5VDC), state steps, or TTL
  • Connector options: Molex Micro-fit 3mm, Hirose 2mm
  • Powering options: 5VDC, 7-35VDC (~500mW)




  •  
  • Target gases: combustible, toxic, refrigerant & oxygen
  • Various MOS and electrochemical sensor heads available
  • Ports compatible with PowerKnowz™/Panterra
  • Bi-color LED indicators, LCD display and alarm beeper
  • DPDT master relay standard. SPST zone relays optional
  • Connector options: Hirose 2mm, terminal block
  • Powering options: 12-14VDC, 7-40VDC (~16W fully loaded)