106 / 206-RF | Singer Valve Inc

By: Singer Valve  09-12-2011
Keywords: Valve, flow control, Control Valves

  • Accurately limits flow to a pre-set maximum
  • Easily adjustable flow limit
  • Paddle-style orifice plate included
  • Optional orifice plate housing

The 106-RF and 206-RF rate of flow control valves are based on the 106-PG or 206-PG main valves.

The valve is ideal for limiting the flow to a pre-determined maximum (via maintaining a continuous pressure differential across an orifice). When the pressure differential is less than the set-point, the valve opens, allowing flow to meet predetermined demand. At the desired maximum set-point, the pilot reacts to small changes in sensing pressure and controls the main valve position by modulating the pressure above the diaphragm.

When the pressure drop across the orifice exceeds the set-point, the valve closes slightly, limiting the flow to the pre-set maximum. The orifice is usually sized to generate a pressure differential of 3 to 5 psi / 0.2 to 0.35 bar at the desired flow. Adjusting the pilot setting permits the maximum flow to be changed in the field above or below the original point.

Keywords: Control Valves, flow control, Pressure Differential, Valve,

Other products and services from Singer Valve


160 | Singer Valve Inc

The pilot guide and stem location above the diaphragm shall eliminate debris build-up and sticking as well as minimize turbulence and false readings on the diaphragm. The pilot stem shall be guided by a Delrin bushing in the spring casing above the diaphragm and totally removed from the flow of water in the main pilot chamber.


106 / 206-PR-SM | Singer Valve Inc

The pilot reacts to small changes in pressure to control the valve position by modulating the pressure above the diaphragm in the lower operating chamber. Should the primary pilot system and / or main valve fail to control the downstream pressure, the independent back-up pilot system will begin to operate. The 106-PR-SM and 206-PR-SM series control valves are engineered to be used anywhere pressure reducing valve failure is unacceptable.


AC | Singer Valve Inc

It’s ideal for applications where large pressure differentials preclude the use of standard automatic control valves and varying flows make orifice plates ineffective. The 106-AC series control valve is designed to solve high pressure drop problems by allowing smooth control and protection from cavitation damage. The AC control valve contains two heavy stainless steel sliding cages that maximize the full flow capacity.