Mass Flow Meters - Digital Gas Flow Meter Products by Alicat Scientific

By: Alicat Scientific  09-12-2011
Keywords: flow meters, Flow Meter, Mass Flow Meters

Alicat M Series Digital / Analog Mass Flow Meters

  • Simplicity
    Alicat M series mass flow meters were designed to be used as a stand-alone device. With the native display, a user can easily change the configuration of the meter without the need for computers, complicated software or scripts.

  • Alicat M series flow meters require very little power to run thereby reducing operating costs. M series flow instruments also have less pressure drop when compared to similar flow devices. Reduced pressure drop means more process fluids go into your process and not into your measurement devices. The M series mass flow meters also measure pressure, temperature and volumetric flow in addition to mass flow which means fewer instruments you will have to buy and install. Adding a allows users to see how much media has flowed through the system, making it a great way to monitor usage and identify waste.
  • Versatility
    M series mass flow meters are available in any flow range from 0.5SCCM through 2000+SLPM. They are equipped with multiple analog outputs in addition to the RS-232 digital output. The M series meter can also be orderd as a to make a stand alone secondary calibration standard or flow verification meter.
  • Small Size
    The M series mass flow meter has a footprint of 2.38'X1.050' through 5.2'X2.9' making it easy to integrate into systems or to use as a stand-alone calibrator.
  • Dependability
    There are currently over 60,000 Alicat products in service around the world. Alicat mass flow meters are being used in processes like leak detection, flow monitoring and atmospheric testing.
    All Alicat Scientific mass flow meter calibrations are .
  • Digital or analog mass flow meters, regardless of manufacturer, serve a single purpose..to measure the flow of gases through a system. Mass flow meters must be accurate, versatile, dependable and cost effective.The Alicat Scientific's M series digital / analog mass flow meter was designed to meet and exceed the requirements that customers place on mass flow meters:
     

    Features and Benefits of Alicat M series mass flow meters

    Measured Parameters
    • Mass Flow
    • Volumetric Flow
    • Pressure (PSIA)
    • Temperature (° Celsius)Displays
    • All measured parameters are displayed in real time on the . Any measured parameter can be brought to the center of the screen. are also available.
    • Versatility
    • Multiple process measurements in one device to reduce the need for other measurement devices.
    • Response speed can be adjusted by the user to suit the application
    • Multiple analog & digital outputs to make communicating with the device easier and less costly.
    • allows the flow meter to measure flow at 1/100th of its full scale rating
    • 30-Gas Select on all units reduces inventory requirements
    • The max flow rate for the mass flow meter does not change, regardless of gas!
    • "Tare" feature allows the user to zero the unit at any time
    • Customizable units of measure for added ease of use
    • Optional allows for panel mount of the display with full push-button control in embedded applications30 factory installed, user selectable, gas calibrations:
    • Air
    • Argon
    • Methane
    • Carbon Monoxide
    • Carbon Dioxide
    • Ethane
    • Hydrogen
    • Helium
    • Nitrogen
    • Nitrous Oxide
    • Neon
    • Oxygen
    • Propane
    • Butane
    • Acetylene
    • Ethylene
    • Iso-Butane
    • Krypton
    • Xenon
    • Sulfur Hexaflouride
    • 75% Argon + 25% C02
    • 90% Argon + 10% C02
    • 92% Argon + 8% C02
    • 98% Argon + 2% C02
    • 75% Argon + 25% Helium
    • 75% Helium + 25% Argon
    • 75% CO2 + 25% Argon
    • Helistar® A1025
    • Stargon® CS
    • 95% Argon + 5% CH4
    • Nitric Oxide to 100%
    • Nitrogen Triflouride to 100%
    • Ammonia to 100%
    • Chlorine to 100%
    • Hydrogen Sulfide to 100%
    • Sulfur Dioxide to 100%
    • Propylene to 100%
    • Nitrogen Dioxide to 0.5% in an inert carrier
    • Refrigerant gases to 100%Communication
    • RS-232 output of all measured parameters
    • Optional
    • Optional compatible communication standard
    • Optional compatible communication standard
    • Choice of analog output of main parameter
    • 0-5Vdc, 1-5Vdc, 0-10Vdc, or 4-20mA
    • Local DisplayCustomization
    • Alternate STPs for mass units
    • Lower pressure drops cut material costs.
    • 0-10Vdc or 4-20mA outputs; 2 channels
    • Totalization
    • Gas blend calibrations
    • Alternate units of measure (SCFM, SCFH, etc)
    • Battery pack for portable operation
    •
    •
    • No display units for OEMs
    • Bi-directional flow capability
    version available.
    version available.
     
    Copyright © 2011 - Alicat Scientific, Inc. - All rights reserved

    Keywords: Flow Meter, flow meters, Mass Flow, Mass Flow Meter, Mass Flow Meters, Measurement Devices, Process Fluids,

    Other products and services from Alicat Scientific

    09-12-2011

    Mass Flow Controller, Gas and Volumteric Flow Control Products by Alicat Scientific Inc

    Demand for mass flow controllers is growing and customers are requiring MFCs that are easy to use, fast, reliable, accurate, cost effective and robust.The Alicat mass flow controllers are engineered to meet the following design criteria. Digital / Analog Gas Flow ControllersMass flow controllers were originally designed to take the guess work out of precision gas flow control.