PAINT BOOTH $110,000

PAINT BOOTH  $110,000 from HVAC SYSTEMS LTD

By: HVAC SYSTEMS LTD  31-03-2014
Keywords: Paint Booth, Spray Booths

One (1) Truck Spray Booth – Supply Only Dimensions: Overall outside Dimensions: 16’-0" Wide x 50’-0” Long x 16'-0” High. Construction: All panels are pre-punched every 6”, (bolted design) with 3/8” holes and are manufactured from 18 gauge galvanized G90 steel. Ventilation System: Two (2) 30” diameter Exhaust Fans with non-sparking aluminum blades are provided. Each fan is powered by a 575V / 3-PH hi-efficiency motor. Air velocity is designed to conform to OSHA, NFPA and EPA regulations. Lighting: Forty (40) 2’ x 4’hi-efficiency T-8 style fluorescent light fixtures and forty (40) 2’ x 4’ clear tempered glasses are provided. Each light fixture includes mounting brackets (tubes not included). Exhaust Chamber: One (1) Exhaust Chamber size 16’W x 12’H – accordion type. Stiffeners: One (1) set of Side Stiffeners and Roof Stiffeners. Man Doors: Two (2) Man Doors size 36”W x 84”H. Front Doors: One (1) set of Front Doors size 14’W x 14’H. Air Supply Filter Box: One (1) Air Supply Filter Box size 16’W x 3’H x 10’D. Air Supply Filters: Air Supply Filters will be supplied. Andreae Media Filters: Andreae Media Filters will be supplied. Gaskets: All Gaskets will be provided as necessary. Handles: All Handles will be provided as necessary. Magnets: All Magnets will be provided as necessary. Hardware: All Hardware will be provided as necessary. Floor Channels: One (1) set of Floor Channels. P a g e HVAC Systems Ltd. February 18, 2014 Interlock Kit One (1) Interlock Kit which includes a combination of the following: • One (1) Solenoid Valve • One (1) Air Flow Switch • One (1) Magnahelic Manometer One (1) Single Stage Air Make up Unit – 26,000 CFM Features Included: • This unit is “CSA Approved” • All Units are Pre-Piped and Pre-Wired • All Units are Factory Tested to Insure Trouble Free Start-Up and Operation • All Panels 18 Ga. Galvanized G90 Anti-Corrosion • Double Wall Insulated Panel to minimize heat loss and noise • 80° F Discharge Temperature • All Seams are filled with Sealant • Maxon burner with 2.6 MBTU/HR heat capacity • Power supply: 575 V / 3 PH / 60 Hz • Remote control panel with on/off switch, summer/winter selector switch, cycle selector switch and temperature control. • Required to Supply Replacement Air for the Paint Booth Exhaust Fan • Natural Gas Fired • Designed for Indoor/ Outdoor Installation with 0.75”s.p. • Delhi Blower with Forward Curved Blades and External Supported Flange Bearings • V-Bank Style with 2” Cleanable Air Intake Filters. Access Door Provided For Easy Maintenance and Servicing • Components for the Gas Train Build Up Using Maxitrol and Asco Products: - Main Gas Valve - Pressure Regulator - Solenoid - Water Regulator - High Pressure Gas Valve - Pilot Pressure Regulator - Pilot Gas Valve • Components for the Air Make-Up Unit constructed Using Maxon Products: - Burner - Flame Rod 4 | P a g e HVAC Systems Ltd. February 18, 2014 - Spark Plug • Overload Protection for Air Make-Up Unit - Motor fuse protection - Terminal Strips for Field Wiring - Lighting Contactor for Booth Lights • Test-port for measuring pressure drop across the burner that has adjustable profile. **Note: Installation and Electric Drawings will be supplied** | P a g e HVAC Systems Ltd. February 18, 2014 Customer Responsibilities: Delivery Crate Exhaust Ducting Air Supply Ducting Mechanical Installation Electrical Installation Sprinklers Gas Plumbing $110,000

Keywords: Paint Booth, Spray Booths

Other products and services from HVAC SYSTEMS LTD


25-06-2010

hvacsystemsltd.com 403-726-1521

         About Us Power Generation - Wind, Generators, Turbine Installation & Maintenance, Steam Turbines HVAC Systems Ltd. is an established industrial, commercial and mechanical electrical contractor.  We specialize in the following services: Plumbing - new installs, valves, sewer,water, boilers(Cleaver, Brooks), gas pipe, super hot and more.  Plumbers Union Local 496. Electrical - new installs like panel, general wiring.  Retro upgr


25-06-2010

UNIT HEATER 403-726-1521 www.hvacsystemsltd.com

  unit heaters/ duct furnaces True performance and rugged durability Designed to last longer and perform better Separated Combustion Unit Heaters at a glance: Ideal for hard-to-heat applications requiring fresh air for combustion due to excessive dust, dirt and humidity or negative pressure Easy access to components through a hinged door Heat capacity ranging from 45,000–300,000 Btuh Unit Heaters at a glance: Meets a wide range of residential and commercial heating applications Heat capacit


25-06-2010

HEATING PRODUCTS UNIT HEATER 403-726-1521 www.hvacsystemsltd.com

  Ideal for hard-to-heat applications requiring fresh air for combustion. Compact cabinet design – 45,000-75,000 Btuh models. Hinged Door – provides easy access to components. Concentric Venting – allows single penetration for faster installation. Sidewall Venting – eliminates roof penetrations. Self-Diagnostic Board with LED Display – improves troubleshooting efficiency and accuracy. Stainless Steel Heat Exchanger – increases efficiency and durability. Heating capacities from 45,000-300,


25-06-2010

Split Systems 403-726-1521 www.hvacsystemsltd.com

  Minimal air resistance for better performance. 1.5- to 5-ton capacities. Uncased (C33) and full-cased models. C33 has up-flow configuration. CH33 and CH23 have horizontal configuration. CR33 has down-flow configuration. Large face area coil allows for high-efficiency operation. Copper-rifled tubing and enhanced aluminum fins improve transfer. Long-lasting, painted galvanized cabinet and plastic drain pans


25-06-2010

Roof Top heating cooling units 403-726-1521

  Saving Energy with Intelligence™ Up to 11.0 EER and 13.0 IPLV. Integrated Modular Controller – digital accuracy and enhanced unit performance with over 200 unit control functions. Impressive diagnostic capability provides simple troubleshooting to reduce operation and service cost. SmartWire™ System – simplifies field sensor or thermostat installation through advanced connectors that are keyed and color-coded to help prevent miswiring. Not only is the wire coloring scheme standardized a


25-06-2010

HEAT TRANSFER PRODUCTS 403-726-1521 www.hvacsystemsltd.com

  Finned Tube RadiationEngineered Air offers an extensive line of hot water, chilled water and steam heating products for commercial, industrial and institutional application. Unit HeatersEngineered Air offers an extensive line of hot water, chilled water and steam heating products for commercial, industrial and institutional application. CoilsEngineered Air offers an extensive line of hot water, chilled water and steam heating products for commercial, industrial and institutional applica


25-06-2010

HVAC SYSTEMS LTD

  Home :: Profile :: Products :: Case Studies :: Careers :: Related Sites :: Contact Us Products Cooling :: FW Series Direct Fired Indirect Fired Heat Recovery Heat Transfer Cooling FW Series Air Handling Controls IAQ Airtex Radiant Panels Our FW series of packaged air conditioners are completely custom designed to meet your needs, the units can be configured in cooling only or heat cool design. We offer a large assortment of both new and retrofit multi-zone designs. This product can also


25-06-2010

cooling unit 403-726-1521 www.hvacsystemsltd.com

  Home :: Profile :: Products :: Case Studies :: Careers :: Related Sites :: Contact Us Products Cooling :: FW Series Direct Fired Indirect Fired Heat Recovery Heat Transfer Cooling FW Series Air Handling Controls IAQ Airtex Radiant Panels Our FW series of packaged air conditioners are completely custom designed to meet your needs, the units can be configured in cooling only or heat cool design. We offer a large assortment of both new and retrofit multi-zone designs. This product can also


03-02-2010

makeup air systems 403-726-1521 www.hvacsystemsltd.com

quality replacement hvac equipment -- Heat Recovery Heat Transfer Cooling Air Handling Controls IAQ Airtex Radiant Panels HE SeriesThe HE series make up air units offer the most efficient available method to heat make up air. Direct fired make up air heaters may be considered to be 100% efficient because no heat is vented to the atmosphere. RE SeriesThe RE series mix air units offer the most efficient available method to heat mix air. Direct fired make up air heaters may be considered to be 100


HVAC SYSTEMS LTD 403-726-1521 from HVAC SYSTEMS LTD thumbnail
03-02-2010

HVAC SYSTEMS LTD 403-726-1521

energy eficent equipment, high end quality